Structured Cabling & Fibre

The physical layer everything else runs on.

The cabling and fibre plant underneath every network — surveyed, installed, tested and certified, then documented for handover.

Our delivery methodology

Survey to sign-off, done by the book.

A repeatable 7-phase process. Every phase produces a concrete deliverable — a report, a design pack, a certification, a sign-off — so you always know exactly what you’re getting, and when.

7-phase delivery Documented gates Certified & warrantied
  1. Site Survey & Scoping

    01

    Deliverable Signed-off site survey report with pathway routes, measured cable runs, riser/containment routes and outlet counts

  2. Cabling Design

    02

    Deliverable Signed-off design pack: floor-plan cable routes, rack elevations, backbone topology and port/labelling schedules

  3. Procurement & RAMS

    03

    Deliverable Approved bill of materials plus method statement, RAMS and permit-to-work before any site mobilisation

  4. Containment & Rack Build

    04

    Deliverable Installed cable tray, trunking, cabinets and rack build inspected and signed off against the design

  5. Cable & Fibre Install

    05

    Deliverable Terminated Cat6/6A outlets and fusion-spliced fibre backbone, with OTDR splice traces logged per strand

  6. Test & Certification

    06

    Deliverable 100%-pass Fluke DSX permanent-link copper reports and bidirectional OTDR / light-source fibre certification

  7. As-Built Handover

    07

    Deliverable As-built handover pack, labelling schedule and system warranty registration signed off at final acceptance

The architecture

How we build the cabling plant

A structured hierarchy from the comms room down to every outlet — certified and documented end to end.
01

Comms room / MDF

Fibre entry & core patching

02

Fibre backbone

OS2 / OM4 between floors

03

Floor distributor

Per-floor switch & patch

04

Cat6A horizontal

To every outlet & AP

05

Certified & labelled

Tested and documented

What we provide

Survey & design

Site survey, pathway and cabinet design, and a bill of materials matched to the building.

Copper & fibre install

Cat6 / Cat6A copper and single- or multi-mode fibre, neatly dressed and labelled.

Backbone & risers

Inter-building and inter-floor fibre backbone, splicing and termination.

Test & certify

Every link tested and certified to standard, with results handed over.

Racks & containment

Cabinets, trunking, tray and cable management built to last.

As-built documentation

Labelling schedules and as-built drawings for a clean handover.

What you receive

A complete evidence pack, not just a working system.

As-built drawings (floor-plan cable routes, rack elevations and backbone topology) issued in PDF and native CAD

Copper certification reports — per-outlet permanent-link results from a calibrated field tester (e.g. Fluke DSX)

Fibre certification reports — bidirectional OTDR traces plus insertion-loss / light-source-and-power-meter results per strand

Port, patch and cable labelling schedule with the ANSI/TIA-606 administration record

Operation & maintenance handover manual covering rack layouts, patching schedules and moves-adds-changes guidance

System performance warranty certificate covering the installed copper and fibre plant

Standards & assurance

Cabling performance

Copper and fibre plant is delivered to TIA-568 / ISO/IEC 11801 transmission and ISO/IEC 14763-3 fibre-testing requirements, with every link 100% certified before acceptance.

Labelling & administration

All outlets, patch panels, cabinets and pathways are labelled and documented to ANSI/TIA-606 administration, with pathways and bonding installed to TIA-569 and ANSI/J-STD-607 earthing practice.

Workmanship warranty

The installed system carries a manufacturer-backed performance warranty on the certified channels, supported by a defect-liability period covering workmanship and termination quality.

Where we deploy it

Tuned to the environment.

Education & Campus

Campus-wide Wi-Fi with student and BYOD onboarding, backed by structured cabling.

Hospitality

In-room Wi-Fi 7 on a wall-plate built for hotels, with branded guest onboarding.

Enterprise & Manufacturing

Plant-wide wireless, surveillance and servers integrated into one estate.

Scope a structured cabling & fibre project

Tell us the site and the outcome you need, and we'll design, deliver and quote it — to standard, documented and certified.