Structured Cabling & Fibre
The physical layer everything else runs on.
The cabling and fibre plant underneath every network — surveyed, installed, tested and certified, then documented for handover.
Our delivery methodology
Survey to sign-off, done by the book.
A repeatable 7-phase process. Every phase produces a concrete deliverable — a report, a design pack, a certification, a sign-off — so you always know exactly what you’re getting, and when.
-
Site Survey & Scoping
01Deliverable Signed-off site survey report with pathway routes, measured cable runs, riser/containment routes and outlet counts
-
Cabling Design
02Deliverable Signed-off design pack: floor-plan cable routes, rack elevations, backbone topology and port/labelling schedules
-
Procurement & RAMS
03Deliverable Approved bill of materials plus method statement, RAMS and permit-to-work before any site mobilisation
-
Containment & Rack Build
04Deliverable Installed cable tray, trunking, cabinets and rack build inspected and signed off against the design
-
Cable & Fibre Install
05Deliverable Terminated Cat6/6A outlets and fusion-spliced fibre backbone, with OTDR splice traces logged per strand
-
Test & Certification
06Deliverable 100%-pass Fluke DSX permanent-link copper reports and bidirectional OTDR / light-source fibre certification
-
As-Built Handover
07Deliverable As-built handover pack, labelling schedule and system warranty registration signed off at final acceptance
The architecture
How we build the cabling plant
Comms room / MDF
Fibre entry & core patching
Fibre backbone
OS2 / OM4 between floors
Floor distributor
Per-floor switch & patch
Cat6A horizontal
To every outlet & AP
Certified & labelled
Tested and documented
What we provide
Survey & design
Copper & fibre install
Backbone & risers
Test & certify
Racks & containment
As-built documentation
What you receive
A complete evidence pack, not just a working system.
As-built drawings (floor-plan cable routes, rack elevations and backbone topology) issued in PDF and native CAD
Copper certification reports — per-outlet permanent-link results from a calibrated field tester (e.g. Fluke DSX)
Fibre certification reports — bidirectional OTDR traces plus insertion-loss / light-source-and-power-meter results per strand
Port, patch and cable labelling schedule with the ANSI/TIA-606 administration record
Operation & maintenance handover manual covering rack layouts, patching schedules and moves-adds-changes guidance
System performance warranty certificate covering the installed copper and fibre plant
Standards & assurance
Cabling performance
Copper and fibre plant is delivered to TIA-568 / ISO/IEC 11801 transmission and ISO/IEC 14763-3 fibre-testing requirements, with every link 100% certified before acceptance.
Labelling & administration
All outlets, patch panels, cabinets and pathways are labelled and documented to ANSI/TIA-606 administration, with pathways and bonding installed to TIA-569 and ANSI/J-STD-607 earthing practice.
Workmanship warranty
The installed system carries a manufacturer-backed performance warranty on the certified channels, supported by a defect-liability period covering workmanship and termination quality.
Where we deploy it
Tuned to the environment.
Education & Campus
Campus-wide Wi-Fi with student and BYOD onboarding, backed by structured cabling.
Hospitality
In-room Wi-Fi 7 on a wall-plate built for hotels, with branded guest onboarding.
Enterprise & Manufacturing
Plant-wide wireless, surveillance and servers integrated into one estate.
Scope a structured cabling & fibre project
Tell us the site and the outcome you need, and we'll design, deliver and quote it — to standard, documented and certified.